Specifications include, but are not limited to: Approximate Shipping Height: 14'-4" 7936.00 Complex (Base) (1) 11'-8" x 64'-0" Modules and (8) 13'-8" x 64'-0" Modules ***Nominal 124' x 64' *** Occupancy: Education Construction Type VB State Code Requirements & Insignias IBC / Ga Georgia State Approval State Codes Only - No Local Codes Are Quoted 1.00 Additional KIP Load Plan Sheet Seismic Zone "C" {Seismic data is based on site soil class D "Stiff Soil"} 140 MPH Wind Speed 20lb. ground snow load Roof live load 20 lb. Destination: 191 Evergreen Lane, Cedartown, GA 30125 Chassis 64.00 11'-8" wide outrigger w/ 95.5" I-Beam spacing Outriggers & Crossmembers spaced (As Required) 512.00 13'-8" wide outrigger w/ 95.5" I-Beam spacing Outriggers & Crossmembers spaced (As Required) 12" I-Beams (M12x10) Hitches are detachable New tires New Tires are Provided - Drivers are responsible for spares Axle quantity will be calculated as required Under-slung axles are included {Box-out for under-slung axles} Floor Section Standard bottom board material Nylon Impregnated 2"x8" Floor joist @ 16" O.C. (12' Wide Modules) 2'x8" Double Perimeter Included (Full Perimeter) 3/4" Floor sheathing/decking Floor decking held back 5" (at mate-line where applicable) 2"x6" per-lines at mate-lines (where applicable) 7286.00 VCT {Armstrong brand} Installed per the print 1/8" Viny Composite Tile in the Balance 650.00 Armstrong Corlon commercial roll-vinyl Located in the Restrooms and in the Janitor's Closet Only. 2.00 Recessed entry Treated wood 2x4 members and Forticrete Decking @ recessed entry *** With Coin Flooring *** Wall Section 514.00 2"x4" Interior wall height: 8'-6" {Unless otherwise noted, interior walls will be constructed with #2 2x4 studs 16"o.c. with single 2x4 top and bottom plates} 224.00 Double mateline walls constructed per print 2x6 Exterior wall height 8'-6" {Double top-plate on exterior walls, as required} Fire rated walls constructed as required Please note that @ the mate-line the gypsum will be held back 16 or nearest stud unless the stated otherwise. Interior trim package: standard battens {Unless otherwise noted} 5/8" VCG (Vinyl covered gypsum - Type "X") 1568.00 FRP wall panel laid-up on gypsum (Class "C") Full height FRP located in Restrooms and Janitors closets (FRP on 5/8" Gypsum Color: TBD) {F.R.P. = Fiberglass Reinforced Panels will be installed over raw gypsum and include vinyl base coving} 1208.00 4" VCB {Vinyl Cove Base} Balance (Cove Base Color: TBD) 196.00 6" VCB {Vinyl Cove Base} Restrooms & Janitor's closet (Cove Base Color: 67-2 GRAY) 1.00 Special Items: Plumbing wall in restroom areas (per the plan)