Specifications include, but are not limited to: 1.2 On each level of the dwelling unit including basements, but excluding crawl spaces and unfinished attics at least one wireless battery operated or hardwired approved smoke detector in proper operating condition must be present. All smoke detectors are to be replaced. BATTERIES MUST BE 10 YEAR TYPE. Smoke detectors must be installed in accordance with and meet the requirements of the National Fire Protection Association Standards (NFPA) 74 or its successor standards. If a hearing impaired person is occupying the dwelling unit, the smoke detectors must have an alarm system designed for hearing impaired persons as specified in NFPA 74. Smoke detectors shall be located as follows (IAC 661.210.3(11) : On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms. In each room used for sleeping purposes. In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics. To include combination smoke/carbon monoxide detectors where required per City code. 1.3 REPLACE DAMAGED CEILING FAN: Replace ceiling fan with new, average priced, owner approved, energy star rated fan. All work performed under IRC and NEC Codes. Must pass City Inspection. Location: DINING ROOM 1.4 GFCI OUTLET/S: Replace existing outlets within 6' of a water source with GFCI protected duplexes per code. All wiring must be concealed and installed under NEC and IRC codes. Location: Kitchen & Bathroom 1.5 GFCI OUTLET/S: Replace all existing BASEMENT GFCI protected duplexes per code. All wiring must be concealed and installed under NEC and IRC Codes. All wiring must be concealed and installed under NEC and IRC codes. Location: Basement