Specifications include, but are not limited to: REPLACE ELECTRIC MAIN SERVICE. Provide and install new 200/150 amp electrical service at location as required by Code and/or utility company. To include new panel and wiring (unless otherwise specified), new service wire, head, straps, disconnect, ground rod and wire if required, circuit panel and circuit breakers, connection of wiring into new panel, fittings, labels and trim. All work performed under the NEC and IRC Codes. Contractor is responsible for passing inspection.; REPLACE OUTLET(S) WITH GROUNDED. Replace existing outlets with grounded receptacles. Repair any affected surfaces. All work performed under NEC and IRC Codes. Must pass inspection. Location: THROUGHOUT 1ST FLOOR; MISSING GLOBES: Install new protective globe or basket. All work performed under IRC Codes. Location: BASEMENT; GFCI OUTLET/S: Replace all existing BASEMENT GFCI protected duplexes per code. All wiring must be concealed and installed under NEC and IRC Codes. Location Basement; REMOVE DAMAGED DOOR AND INSTALL NEW INTERIOR DOOR (1). Provide and install new prehung 1 3/8" hollow core door(s) and knot free trim. Size to fit existing opening. Installation includes new lock set. Prepare surface, prime, and 2 coats high grade interior paint or stain and finish with minimum of 2 coats of polyurethane, sanding between coats to smooth finish. Color and type of finish is owner's choice. All work performed under IRC Codes. Lead safe work practices. Location: Basement 1 Room Entrance;