1. Installation of approximately 4,680 linear feet of 24‐inch diameter gravity sanitary sewer, including approximately 370 linear feet of 24‐inch diameter sanitary sewer installed in a steel casing under Interstate 280 and Spencer Creek, and related manholes and appurtenances; 2. Installation of approximately 2,110 linear feet of 8‐inch diameter gravity sewer, and related manholes and appurtenances; 3. Installation of approximately 5,830 linear feet of 12‐inch diameter sanitary sewer force main, including air release manholes, air release valves, fittings, and other appurtenances; 4. Site work, including mass grading as shown on the Drawings; 5. Site dewatering as required for construction, and; 6. All other work as required by the contract documents.