Specifications include, but are not limited to: Furnish and install riprap Class 1; Excavate and legally dispose offsite petroleum contaminated soil.; Undercut, dispose onsite, refill with MSHA #2 or #57 stone and compact per specified requirements at trench areas only.; Imported screened topsoil and fine graded in place - no material larger than ¾” in mix; Sodding; Furnish and install MSHA #2 stone; Furnish, install, maintain, and remove super silt fence and grade/re-stabilize; Furnish and install “Leafgro” or equal to amend topsoil to specified organic content. Quantity based on amount of amendment used.; Furnish and install 5% soil cement 1' deep; Furnish and install 6% hydrated lime 1' deep.; Removal of existing sidewalk and spoil as necessary, dispose of legally offsite, install new 5" sidewalk with 6x6 10/10 welded wire mesh.; Saw, cut and removal of existing curb and gutter and dispose of legally offsite, install new curb and gutter to match existing.; 4" CMU wall**; Fire Alarm Strobe: Provide 15, 30, 60, 75, or 110-CD ceiling or wall-mounted strobe and 50-ln/ft of 14 AWG THWN stranded fire alarm cabling in ¾" conduit minimum. Provide all programming and testing.; Telephone Drop: Provide a CAT-5 E telephone jack complete with testing and termination. Include 300-ft of CAT-5 E plenum cable.; Video Drop: Provide video jack and plates as specified complete with testing, termination and labeling. Include 50-ft of RG-6/U coaxial plenum cable and video tape.; Speaker: Provide PA system ceilingmounted speaker including back box, 200- ft of cabling in ¾" conduit and programming.