Remove existing wet and damaged insulation to the existing insulation and dispose of legally. (Include 400 square feet of insulation in base bid) Furnish and install new ½” polyisocyanurate coverboard insulation, mechanically attached to the steel deck. Fastening pattern shall comply with Manufacturer’s I-90 wind uplift requirements and corner and perimeter fastening shall be enhanced to meet ASCE-7 design criteria. All polyisocyanurate insulation shall meet ASTM C 1289-06, Type II, Class 4, Grade 1. Polyisocyanurate crickets and saddles need to be installed at the high sides of units and between water outlets. All polyisocyanurate insulation shall be meet ASTM C 1289-06, Type II, Class 1 Grade 2 (20 psi) Furnish & install tapered edge strip to transition from ½” to zero, at drains and saddles. Furnish and install .060 attached TPO roof system Class A fire rated roof system according to manufacturers’ published specifications and requirements, Rhino Bond preferred. Furnish and install new ES-1 rated coping cap or fascia metal as specified at perimeters. No shop fabricated coping. Paint all gas lines yellow. Furnish & install new polymer gas line supports. Dura-Blok is basis of design. Furnish & install sixteen new vent caps. Gauge & style to match existing like kind & quality. Remove existing damaged skylight and permanently close with decking and roofing material to match the new roofing system. Furnish & install walk pads at access hatch and the service side of all HVAC units. Furnish manufacturer’s Twenty-year material & workmanship warranty with 72mph wind coverage. Manufacturer’s warranty must include perimeter metal.