1 ea WALK IN COOLER
Custom cooler
Interior Dimensions: 7'‐1" x 6'‐7" x 6'‐10 5/8"
Walls: 4" Class 1 ‐ Foamed in place Urethane
Exterior: Galvalume ‐ Embossed 26 Ga
Interior: Galvalume ‐ Embossed 26 Ga
Ceiling: 4" Class 1 ‐ Foamed in place Urethane
Type: Standard
Attachment: Lock Down
Exterior: Galvalume ‐ Embossed 26 Ga
Interior: Galvalume ‐ Embossed 26 Ga
Floor Application: 4" Class 1 ‐ Foamed in place Urethane
Type: Standard 1000# ERA
Finish: Aluminum ‐ Smooth Aluminum .100
Doors/Openings:
Door: 34" x 78" Left Swing Out
Recessed 0" with 0" Leveling Sand and 0" Tile & Grout.
Frame: Exterior: Galvalume ‐ Embossed 26 Ga
Interior: Galvalume ‐ Embossed 26 Gal
A Division of Manitowoc FSG Operations, LLC
Plug: Exterior: Galvalume ‐ Embossed 26 Ga
Interior: Galvalume ‐ Embossed 26 Ga
Door/Opening Accessories:
Qty UoM Description
1 ea Door Closer ‐ Kason 1094 (STD)
1 ea Handle ‐ Kason 28 with Locking Assembly (STD)
1 ea Heater Wire, 1 Watt / FT
2 ea Hinge ‐ Kason 1346 Brushed Chrome Adjustable / Spring
Assisted (STD)
1 ea Light Fixture ‐ Kason 1803 LED w/Bulb, Globe & Nightlight
120V 50/60Hz
(STD)
1 ea Switch ‐ Pilot Light Included 120/230V 50/60Hz (STD)
1 ea Thermometer ‐ 2 inch Dial w/6' Lead (STD)
2.83 lf Threshold, Stainless Steel 14 ga
1 ea Refrigeration:
Qty UoM Description
1 ea KPC48MOP‐2EP
PC48MOP‐2EP, 208‐230/60/1, 1/2HP, R448A, Pre‐Charged, Air‐
Cooled,
Hermetic Medium Temp Standard Plus Compressor Unit, Amps:
5.7,
Ambient Temperature: 95
Includes Head Pressure Control Valve (Headmaster), Amps: 5.7,
Ambient Temperature: 95
1 ea KAM16‐052‐1EC‐PR‐8
AM16‐052‐1EC‐PR‐8, 115/60/1, R448A, Medium Temp, Air Defrost,
Standard Unit Cooler, Amps: 0.8
One year parts and labor included
1 ea 1/2 HP 2 ‐ 5 YR Extended Compressor Warranty
REJOICE REFRIGERATION
Remove the old refrigeration equipment. Disconnect the
electrical.
Remove the old box and erect the new box. Pipe the new refrigeration
equipment and drains. Run a new 208‐230 circuit for the new condensing unit.
Reconnect the 110 circuit for the lights. start system up and set
controls.
All old equipment must be removed from the job site and disposed of.