TITLE: 38-Sources Sought Notice SOL: 36C24225Q0090 DUE: 10/30/2024 at 16:00 EST NAICS: 335999 All Other Miscellaneous Electrical Equipment and Component Manufacturing AGENCY: New York Harbor, NY VA Medical Center, 423 E 23rd Street, New York, NY 10010, and BK VA Medical Center 800 Poly Place, Brooklyn, NY 11209. Email all responses only to: Jonatan.rondon@va.gov This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of potential qualifications of all businesses relative to the North American Industry Classification Code (NAICS) 335999. The Department of Veteran s Affairs is seeking all qualified business manufacturer or distributors of small business manufacturers to all the following specifications: The Manhattan VAMC and Brooklyn VAMC requires a brand name only acquisition of Powerex Oil Free Scroll Air Compressors and Desiccant Dryers that will be used with the Steris Endodry Endoscope drying and storage cabinets and the Ivoclar PrograMill PM7 dental milling machine currently in use at the VA Facilities. The two air compressors used at the Manhattan VAMC must meet the following conditions: Air Supply Requirements: Quality: ISO 8573-1:2010 class 1.2.1 Particle Size: Incoming air filtered down to <1 micron in size. Moisture Content: Pressure dew point (PDP) of -40°C or better required and no liquid water. Oil Content: < 0.01mg of oil per cubic meter of compressed air (liquid, aerosol, or vapor oil). Pressure: The below pressures are required at the point of cabinet connection. ENDODRY Cabinet for ADVANTAGE PLUS Endoscope Reprocessor: 58-145 psi (4-10 bar). Volume: The below volumes are required at the point of cabinet connection. ADVANTAGE PLUS Endoscope Reprocessor/ENDODRY Cabinet: Minimum requirement of 4.2 scfm (120 L/min ANR) per cabinet. Flexible Air Hose: A 5-foot (1.5 Meter) line is included with each cabinet. One end will be pre-configured to connect to ENDODRY Drying Cabinet. Open end will be ¼ or 6mm inner diameter and it is the responsibility of the facility to make that connection to their air supply line. Noise Level: No more than 51dB Dimensions: No bigger than 34 x 37 x 41 Electrical: Compressor 208V, three phase Compressor Type: Scroll, oil free. Dryer Type: Desiccant The air compressor used at the Brooklyn VAMC must meet the follow conditions: Air Supply Requirements: Quality: ISO 8573-1:2010 class 3.4.3 Particle Size: Class 3, Incoming air filtered down to <5 micron in size. Moisture Content: Class 4, Maximum pressure condensation point +3 C (+37.4 F) Maximum Oil Content: Class 3, Maximum oil content 1mg/m ^3 Pressure: Continuous 90 110 psi Volume: Continuous 205 l/min or 7.24CFM Dry compressed air, clean and oil-free Compressed Air Tube Hose: 8mm (0.3in) outside diameter connection Noise Level: No more than 51dB Dimensions: No bigger than 34 x 37 x 41 Electrical: Compressor 208V, three phase Compressor Type: Scroll, oil free. Dryer Type: Desiccant Item/Quantity Description: Item Description Mfr. Part # Qty 1 5HP OIL FREE SCROLL COMPRESSOR, 13 GALLON INTERNAL TANK. 116PSI INTERGRATED DESICCANT AIR DRYER W/ FILTER. STARTUP INCLUDED FOR MANHATTAN VAMC POWEREX SES 0508-X-DD 2 2 FILTERS: 2 COMPRESSOR INLET FILTER ELEMENT 4 DRYER PRE FILTER ELEMENT 4 DRYER POST FILTER ELEMENT 1 3 INSTALLATION LABOR, MATERIALS FOR MANHATTAN VAMC 1 4 5HP OIL FREE SCROLL COMPRESSOR, 13 GALLON INTERNAL TANK. 145PSI INTERGRATED DESICCANT AIR DRYER W/ FILTER. STARTUP INCLUDED FOR BROOKLYN VAMC POWEREX SES 0508-X-DD 1 5 INSTALLATION LABOR, MATERIALS FOR BROOKLYN VAMC 1 Place of Delivery: New York Harbor, Manhattan VA Medical Center Warehouse: 423 E 23rd Street New York, NY 10010 and New York Harbor, Brooklyn VA Medical Center Warehouse: 800 Poly Place Brooklyn, NY 11209 THIS IS NOT A SOLICITATION AND DOES NOT OBLIGATE THE GOVERNMENT TO ISSUE A SOLICITATION. Please be advised that the Government will not pay for any information submitted under this announcement. The applicable North American Classification System (NAICS) Code for this requirement is 335999 (All Other Miscellaneous Electrical Equipment and Component Manufacturing). Response Email should contain the following information: Name of firm, Socio-Economic category of the firm, complete address, phone & fax number of contacts.