1 Location is 931 Commonwealth Road, Randleman NC 27317 Latitude 35.821314° North Longitude -79.831628° West 2 Tower is to be a self-supporting structure. 3 Tower Height is to be 396-ft AGL with a 50-ft Fall Zone. 4 Tower will be positioned on the DCS as indicated in the attached Construction Drawings. 5 The Tower Structure shall utilize solid round or angle structural steel members. No other materials or shapes will be given consideration. Note all members must be hot dipped galvanized to prevent corrosion. 6 All structural bolts must meet the ASTM A325 or A490 Specification. 7 The Tower Contractor will provide all materials to Complete the Tower & Foundation Installation. 8 The Tower Contractor will build the Foundation and erect the Tower. 9 The Tower Contractor will provide a detailed set of foundation drawings (sealed by a North Carolina Registered Engineer) showing all details including all rebar sizes and quantities, and concrete volumes. The Tower Contractor shall install the tower foundation. The Tower Contractor may construct the foundation using the most cost-effective method. The type of foundation presented in this Bid shall be designed and constructed in accordance with the Geotechnical Parameters specified in the Subsurface Exploration Report provided by Engineered Tower Solutions. That document is an attachment to this IFB. 10 Any damage to the access road from construction of this tower must be repaired by the contractor so to restore road to the design document condition. If there are repairs required to the existing access road in order to construct the tower those repairs must be included in the bid. The contractor is responsible for tower construction. Civil work will be completed by Civil contractor.