Specifications include, but are not limited to: A. Approximately net usable square feet required are + 8,661 Square Feet. NOTE:Net usable space is a term meaning the area to be leased for occupancy by State personnel and/or equipment. To determine net usable space: 1. Compute the inside area of the space by measuring from the normal inside finish of exterior walls or the room side finish of fixed corridor and shaft walls, or the center of tenant separating partitions. 2. Deduct from the inside area the following: *a. Toilets and lounges *b. Entrance and elevator lobbies *c. Corridors d. Stairwells e. Elevators and escalator shafts f. Building equipment and service areas g. Stacks, shafts, and interior columns h. other space not usable for State purposes VI. ELECTRICAL, TELEPHONE, MAIN SERVICE OUTLETS A. A minimum of 200 120 Volt duplex electrical outlets are required. Unless otherwise approved by the State: 1. All private offices shall have a minimum of (3) duplex receptacles. 2. Electrical service shall support a minimum of (3) duplex receptacles per partial height modular workstation or per person in an open office environment. Service shall be provided by lessor via overhead or under floor distribution system utilizing power poles or other suitable facilities to accommodate the electrical needs of the agency. All connections to the building electrical service shall be by the Lessor. 3. Each Kitchenette or Break Area shall be provided with sufficient electrical circuitry to accommodate a refrigerator, microwave oven, coffee maker and vending machine. Separate circuits are required for this area. 4. (1) Duplex receptacle shall be provided for every 50 linear feet of corridor. 5. (1) Dedicated 20-amp 110-volt circuit with isolated grounds are required in the LAN room. Outlets to be installed 36” from the floor. If more than one LAN room, the requirements above are required for each LAN room. 6. Separate isolated ground circuit for water fountains. 7. (6) dedicated 110-volt electrical circuits with isolated grounds are required. 8. Outlets to be installed no lower than 18 inches (18”) from the floor. B. A minimum of 30 telecommunication outlet boxes is required. Lessor shall provide all conduit and pull strings from above ceiling to outlet boxes. State to install wiring and cover plates. C. A 4’ x 8’ x ¾ thick sheet of fire-retardant plywood shall be installed on a wall in the telecommunications wiring area to serve as a backboard for telecommunications wiring equipment. XV. SPECIAL REQUIREMENTS A. Fire extinguishers and servicing, pest control, and adequate outside trash disposal including provision for the handling of recyclable items such as aluminum cans, cardboard, plastic and paper, if applicable. These responsibilities include providing adequate dumpsters outside and recycling bins as well as a method for the disposal of the recyclable items. These must be emptied on a regular schedule. B. All pesticides must be applied by a licensed technician. C. Lighted exit signs. D. Safety alarm equipment usable by hearing and visually impaired individuals (smoke and/or heat activated strobe for hearing impaired and horn for visually impaired). Alarm and smoke detectors to be wired in. Auxiliary lighting with battery back-up is required.