Amendment:2 Response to request for information
1. Flange Kits: Is the provision of flange kits required in addition to the pump and motor, or is the delivery limited to the pump and motor only? Pump and motor only
2. If required by the supplier, will you be able to provide the tax exemption certificate? YES
3. When submitting proposal ensure that you factor the risk of traffs if applicable.
Amendment:1 Response to request for information
I just wanted to point out this in the spec to ensure are there any required services? This is no serivce requirement. It's a commodotity and delivery only.
The contractor is responsible for: providing all material, equipment and transportation required for the purchase and delivery of one vertical pool pump located at Columbus AFB, MS. Unit is required to be a Speck, BADU Block Multi series Vertical Pump [model 100/250, a nominal flow rate of 562g.p.m., max flow rate of 800g.p.m., a nominal head of 70 ft., rated at 460V, 3 phase] or approved government equal. Current pump is 15 HP, 1740 RPM, 230/460 V, 3 phase with a design flow of 562 GPM and 70’ head. All suction and discharge piping is sch. 80 PVC.
Any questions pertaining to this item are due by March 17, 2025 at 12:00 pm CST.