Page 8 of 9 Page 1 of Page 1 of Page 1 of Page 1 of Page 1 of DESCRIPTION This is not a solicitation but rather a Request for Information (RFI/Sources Sought) for market research purposes only. Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5, is issuing this Sources Sought in order to identify capable firms and obtain information for planning purposes only. Responses must be submitted by 12:00 PM EST, March 17th, 2025. Submit responses to this Sources Sought via email to james.ferro@va.gov All SDVOSB and VOSB firms that respond shall include proof of CVE certification via www.vip.vetbiz.gov. All small business firms that respond shall include proof of small business status via their Representations and Certifications in accordance with (FAR 4.1102 Policy). While SDVOSB/VOSB firms are preferred, all capable firms are welcome to respond to this Sources Sought. All respondents to this Sources Sought shall include as part of their response answers to the below questions and provide any additional pertinent information that supports the answers. If there are any ambiguities in this Sources Sought, please identify them in your response. The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., socioeconomic set-aside, full and open competition, etc.). VA assumes no responsibility for any costs incurred associated with the preparation of responses. Suggested NAICS: 339112 (Surgical and Medical Instruments Manufacturing) Suggested PSC: 6515 (Medical and Surgical Instruments, Equipment, and Supplies) Open to suggestions from the market as to a more proper NAICS and/or PSC, as well as any potential GSA/FSS Schedule SIN categories. Items to be Procured: Manufacturer Part # Item Description Item Quantity ALTASR1B ALTA SMART RECOVERY BUNDLE ALTA SMART RECOVERY BUNDLE WITH ACUMEN IQ/CLEARSIGHT, PRESSURE CABLE FOR ACUMEN IQ/FLOTRAC. Kit contains: ALTASR1, PC2K, EVHRS, HEMPSC100, 50038354001 3 PCCVR PRESSURE CONTROLLER COVER - PCCVR Included with HemoSphere, HemoSphere Alta, and HemoSphere Vita bundles, as well as Acumen IQ cuff, ClearSight cuff, and VitaWave cuff module upgrade kits 3 HEMRLSTD1000 HEMOSPHERE ROLL STAND Accessory 3 ALTA360Y3 ALTA 360 PROGRAM 36MO PLAN Covers Model(s) listed under "Program Highlights" 3 SALIENT CHARACTERISTICS: Must be able to provide advanced homodynamic monitoring. To include continuous non- invasive blood pressure monitoring, tissue oxygenation monitoring, and visualization of left and right heart monitoring parameters on a single screen view. Must provide an arterial monitoring sensor that is compatible with an existing atrial line (Cook Medical Arterial Pressure Monitoring Set G58408) Must have capability for use with Swan-Ganz pulmonary catheter. Must have hypotensive prediction index. Must be able to utilize predictive algorithm software to anticipate hemodynamic instability before it occurs, based on the following parameters: Invasive Monitoring Arterial Blood Pressure (ABP) Central Venous Pressure (CVP) Pulmonary Artery Pressure (PAP) Mean Arterial Pressure (MAP) Cardiac Output (CO) Cardiac Index (CI) Stroke Volume (SV) Stroke Volume Variation (SVV) Systemic Vascular Resistance (SVR) Central Venous Oxygen Saturation (Scv02) Mixed Venous Oxygen Saturation (Sv02) Tissue Oxygen Saturation (St02) Must offer non-invasive monitoring capabilities, which allows for continuous assessment of hemodynamic parameters without the need for invasive procedures. Must be customizable to allow clinicians to select specific monitoring applications based on their needs. So that they can integrate different monitoring technologies, such as non-invasive, minimally invasive, and invasive hemodynamic monitoring options. Must have a second pressure source. Must have at least a 10 inch, touch screen to not exceed 20 inches Must offer clear visibility into trends, parameters, and intervention feedback. Must provide a rolling stand. Must provide a minimum equipment extended warranty of 1 year, to not exceed 5 years. Must be able to provide trade in of the following equipment to include the removal of the equipment: Asset Tag Asset Manufacturer Asset Model Name Serial Number Status Installation Date 42531 EDWARDS LIFESCIENCES CORP EV1000 TPAA839071 In Use 4/13/2015 42528 EDWARDS LIFESCIENCES CORP EV1000 TPAA854510 In Use 4/13/2015 42529 EDWARDS LIFESCIENCES CORP EV1000 TPAA839031 In Use 4/13/2015 42530 EDWARDS LIFESCIENCES CORP EV1000 TPAA839035 In Use 4/13/2015 If you are interested, please e-mail the following information: Company Name: UEI Number: Cage Code: Dun & Bradstreet Number: Person of Contact (including telephone number and email address). Socio-economic status (SDVOSB, VOSB, Woman-Owned, Other etc.). Are you a distributor or a manufacturer? If you are an authorized distributor, please provide confirmation on Company Letter Head. If you are a distributor, who is the manufacturer? Where is the manufacturer located in the world? Do you currently hold a government contract? Contract Number? Type of contract? Are these particular quoted items under contract? With whom (GSA, SEWP, etc )? If GSA what Schedule and SIN? Can your company provide the service for the listed Department of Veterans Affairs locations? Page 1 of Page 1 of Page 1 of Page 1 of Page 1 of Page 1 of Page 1 of Page 1 of Page 1 of Page 1 of Page 9 of 9 Page 9 of 9 Page 1 of Page 1 of Page 1 of Page 1 of Page 1 of Does your firm utilize the suggested NAICS and PSC per this Sources Sought Notice? If not, please suggest a more appropriate NAICS and/or PSC and explain why it s more appropriate? How do you invoice for this service, including rates? What Certifications, State and/or Federal, if any must you have to perform this service? Please list all of your concerns, questions and ambiguities below. Questions will not be addressed directly but will be used by the Government in the event that this Sources Sought would move forward to solicitation. Please provide estimated rates if possible.