THIS IS TO BE AWARDED BASED OFF LOWEST PRICE TECHNICALLY ACCEPTABLE AND PAST PREFORMANCE.
USCGC IDA LEWIS (WLM 551)
SPECIFICATION FOR FABRICATION OF WATERTIGHT AND NON-WATERTIGHT DOORS, HATCHES, AND SCUTTLES
FY2025
Developed By: Jason W. Taylor
(Rev-0, 05 March 2025)
TABLE OF CONTENTS
Revisions Record. iii
Consolidated List of References. iv
WORK ITEM 1: Fabrication of Water Tight and Non Water Tight Doors, Hatches, and Scuttles 5
Revisions Record
This page is used to record specification revisions, which may have occurred subsequent to a Revision 0 (Rev-0) package. Information listed is intended to provide contractors and field unit personnel a means to ensure all the current specification revision pages are present when reviewing or utilizing this specification package.
DATE
REV#
WORK ITEM#
CHANGES MADE
NOTE : All work item and paragraph numbers listed above for a given revision correspond to same numbers in the previous revision. This revised specification is self-contained with all of the above listed changes incorporated.
Consolidated List of References
The below-listed documents form a part of this specification to the extent specified herein. Approval/publication dates or revision dates/numbers are also identified, to ensure that same document versions are used at the time of specification writing and during contract execution.
All Coast guard drawings, technical publications, and standard specifications will be provided to contractors by the Coast Guard at an appropriate time, or upon request, free of charge. Other Government documents may be accessed – free of charge – from links located on the SFLC website. Commercial sites provide access to their respective documents.
COAST GUARD DRAWINGS
Coast Guard Drawing 175-WLM 167-001, Rev L, 2014, Structural Closures
Coast Guard Drawing 175-WLM-624-001, Rev F, 1998, Joiner Door Schedule
Coast Guard Drawing 175-WLM-631-002, Rev E, 2000, Paint Schedule
COAST GUARD PUBLICATIONS
Coast Guard Commandant Instruction (COMDTINST) M10360.3, Jun 2006, Coatings and Colors Manual
Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements
Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements
Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2022, Welding and Allied Processes
Surface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), 2022, Requirements for Preservation of Ship Structures
OTHER REFERENCES
Code of Federal Regulations (CFR) Title 29, Part 1915, Occupational Safety and Health Standards for Shipyard Employment
Commercial Item Description (CID) A-A-59316, 2016, Abrasive Materials; for Blasting
Military Specification MIL-A-22262B, March 1996, Abrasive Blasting Media Ship Hull Blast Cleaning
NAVSEA Technical Publication T9074-AD-GIB-010/1688, (TP 1688), July 2012, Requirements for Fabrication, Welding, and Inspection of Submarine Structure
The Society for Protective Coatings (SSPC) Surface Preparation Standard No. 11 (SSPC-SP 11), 2013, Power-Tool Cleaning to Bare Metal
The Society for Protective Coatings (SSPC)/NACE International (NACE) 2007, Joint Surface Preparation Standard SSPC-SP 10/NACE No. 2, Near-White Metal Blast Cleaning
- ITEM 1: Fabrication of Watertight and Non-Watertight Doors, Hatches, and Scuttles
1. SCOPE
1.1 Intent. This work item describes the requirements for the Contractor to fabricate watertight and non-water tight doors, hatches, and scuttles identified in Table 1 in accordance with drawings and references.
Table 1 - Watertight Doors and Scuttle locations
Description
Location
P/N and Description
QTY
Drawing
Watertight Scuttle
Main Deck (1-20-2)
PN: 7
21-inch Diameter Quick-Acting Watertight Flush Scuttle, Steel, 3-Dog, Fwd Hinge (including associated 12” height coaming) hasp and staple.
01 Each
175-WLM 167-001
Watertight Hatch
Main Deck (1-50-1)
PN: 6
QAWTH 1-5-0; 30” x 30” Quick-Acting Watertight Hatch, Steel, (Raised 12-inch coaming, 21” QAWTS (hinge fwd.)), including 12-inch height coaming.
01 Each
175-WLM 167-001
Watertight Door
ATON Shop (1-10-0-Q)
PN: 11
26” x 66” C.O., WT, QA, LH, 10-Dog W/ HASP and Staple, W/O Fixed Light Low Type Cres Hinges. Steel.
01 Each
175-WLM 167-001
Watertight Door
Passageway Main Deck
(1-52-0-L)
PN: 18
Door – 30” x 66” C.O., WT, QA, RH, 10 Dog w/ Hasp and Staple w/ Fixed Light Low Type Cres Hinges, Steel.
01 Each
175-WLM 167-001
Watertight Scuttle
Line Locker (1-0-0-Q)
PN: 9
Scuttle – 18” Dia. C.O., RSD, QA, WT, w/ internal toggle pin lock on scuttle, steel, coaming 12” height.
01 Each
175-WLM 167-001
Joiner Door
Boatswains Storeroom
(1-6-0-Q)
PN: 02
Door, Joiner, steel, 26 x 76 ½”, 1 ½” coaming height, LH, INBD, w/ window and kickout. PNL Req’d.
01 Each
175-WLM-624-001
Joiner Door
Paint Locker (1-9-2-K)
PN: 08
Door, Joiner, steel, 26 x 76 ½”. 1 ½” coaming height, RH, FWD, Fumetight window & kick-out panel REQ’d. LOC 4” FWD FR 13.
01 Each
175-WLM-624-001
Weathertight Door
PFD Locker (Starboard) (02-61-1-Q)
PN: 16
Door, 26” x 66” C.O., Weat, RH, w/ hasp and staple, w/o fixed light, steel.
01 Each
175-WLM 167-001
1.2 Government-furnished property
None
2. REFERENCES
Coast Guard Drawings
Coast Guard Drawing 175-WLM 167-001, Rev L, 2014, Structural Closures
Coast Guard Drawing 175-WLM-624-001, Rev F, 1998, Joiner Door Schedule
Coast Guard Drawing 175-WLM-631-002, Rev E, 2000, Paint Schedule
Coast Guard Publications
Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements
Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2022, Welding and Allied Processes
Surface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), 2022, Requirements for Preservation of Ship Structures
Other References
Commercial Item Description (CID) A-A-59316, 2016, Abrasive Materials; for Blasting
Military Specification MIL-A-22262B, March 1996, Abrasive Blasting Media Ship Hull Blast Cleaning
The Society for Protective Coatings (SSPC)/NACE International (NACE) 2007, Joint Surface Preparation Standard SSPC-SP 10/NACE No. 2, Near-White Metal Blast Cleaning
The Society for Protective Coatings (SSPC) Surface Preparation Standard No. 11 (SSPC-SP 11), 2013, Power-Tool Cleaning to Bare Metal
3. REQUIREMENTS
3.1 General.
3.1.1 CIR.
None.
3.1.2 Tech Rep.
Not applicable.
3.1.3 Protective measures. Not Applicable
3.1.4 Interferences. Not Applicable
3.1.5 Testing. All testing to be completed in accordance with drawings and Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2022, Welding and Allied Processes
3.1.6 Shipping. Contractor shall construct container to ship doors and hatches and must include pricing for shipping to CGC IDA LEWIS, CO CWO Michael Scalia, Surface Forces Logistics Command, 2401 Hawkins Point Road, Baltimore, MD, 21226-1797, Building 58.
4. NOTES
None