Specifications include, but are not limited to: Ornamental Security Fence Approved Model – Ameristar Impasse II – Gauntlet Style or approved equal - Install approximately 571 LF of 7’ tall security - Three-rail design - Line post to be on 8’ centers, all posts set in concrete, minimum embed 36” - Black “Perma-Coat” finish with 15-year warranty Ornamental Security Gate - Approved Model – Ameristar Passport IS – Gauntlet Style or approved equal - Install (2) 24 LF cantilever 7’ tall security gate - Three-rail design - Black “Perma-Coat” finish with 15-year warranty Chain Link Fence - Install approximately 676 LF of 6’ tall with galvanized chain link fence - with (3) strands of barbed wire, 12.5-gauge, 4-point barbs, max 5” o.c. - 9-gauge fabric with 2” chain link mesh - 3" WT/LG40 corner, end and pull posts. - 2" WT/LG40 weight line posts, - 1-5/8" diameter, 20-weight, top rail - 7-gauge bottom tension wire. - Line post to be on 10’ centers, all posts set in concrete - Tie in new fencing to existing chain link fence post using all new mechanical ties and new barbed wire as needed. - Selvages: Top and Bottom selvage twisted. - Install (1) 5 LF wide man access gate on the east side of the property. - Install (1) 20 LF wide cantilevered drive thru access gate on the east side of the property. Access Controls – Furnish and install - Shall be compatible with existing AIPHONE system and tie in. - (2) dual height gooseneck-stand with two access control pads with cameras - Minimum 18” diameter concrete pad, embedded 24” in the ground, for gooseneck stand - install a (120v or 240v) single phase circuit, from the nearest service panel in the facility to the gate operator with 1” fiberglass/HDPE or PVC conduit with pull string - install 1” fiberglass/HDPE or PVC conduit for data communication from existing AIPHONE system to the access control pad/camera and operator with pull string - fully integrate the existing system with new components; test & verify proper operation of controls - (4) protective 6” steel pipe bollards, concrete filled, painted safety yellow, embedded 3’ in the ground in minimum 12’diameter hole with concrete. Shall extend 48” above grade and be plumb in all directions - Conduits shall be bored under any concrete or asphalt surfaces. - Data and Electrical must be run in separate conduits Heavy Duty Gate Operators – Furnish and install Approved Model – Hy Security SlideDriver 15 for gates les than 1500lb or approved equal - 18” minimum concrete pad thickness, minimum 8” embedded in the ground - All conduits set in concrete pad and concealed by the operator to prevent tampering - install a (120v or 240v) single phase circuit, from the nearest service panel in the facility to the gate operator with 1” fiberglass/HDPE or PVC conduit with pull string - install 1” fiberglass/HDPE or PVC conduit for data communication from existing AIPHONE system to the access control pad/camera and operator with pull string - (2) free egress detector loop, cut in existing asphalt pavement - (2) reversing detector loop, cut in existing asphalt pavement - Accessories to be installed o Internal solenoid lock kit o Fire & Emergency Access Lock Box (with manual release) and Click2enter. - Data and Electrical must be run in separate conduits