Specifications include, but are not limited to: Freight Elevator at Clifford Hall shall receive the following new components. Contractor to provide and install new equipment as noted below. Existing equipment is to be removed and disposed of by contractor or at the discretion of the owner to be turned over to be stored for later use. 1. Power Unit a. Replacement power unit, must be submersible. 2. Hydraulics a. Retain existing piping, provide new Victaulic seals. b. Remove and replace hydraulic oil. 1) Dispose of exiting oil in accordance with local governance. c. Replace hydraulic packing & seals at jack assembly 3. Controller a. New controller, must be non-proprietary and able to be maintained by groups other than the manufacturer. 4. Solid State Starter a. New starter compatible with existing system and new components. 5. Floor position device and limit switch a. Floor position device and limit switches as required for cab. b. Sensors to be compatible with existing floor elements and elevations. 6. Hoistway a. Hoistway door rollers b. Hoistway door closers 7. Door interlocks, minimum 2 levels of redundancy a. Provide contacts and pickup rollers 8. Door restrictors 9. Door gibs. a. Provide at each door/opening. 10. Escutcheon locks. a. Coordinate lock/key type with local AHJ and Owner. 11. Traveling cable between car and controller. 12. Hoistway wiring. a. Comply with NFPA 70. 13. Top of Car Inspection Station. a. Provide non-proprietary unit compatible with controller and systems. 14. Cab emergency exit a. Comply with applicable state and national code. 15. Signal Fixtures a. Hall call stations – surface mount is acceptable (sized accordingly). 1) Appendix O Sign – engraved in hall stations 2) Communication failure device – incorporate in main hall station. 3) Position indicator in hall stations. b. Hall indicators c. Car operating panel d. In car lantern e. Vandal resistant buttons 16. Door operator a. Linnear style 17. Gate switch a. Minimum 2 levels of redundancy. 18. Car Door Rollers a. Compatible with existing systems and equipment. 19. Cab Fan a. Designed per current code requirements. 20. Door Edge a. Full length electric eye safety edge with 3D detection system. 21. Signage a. Replace existing signage to meet current codes. 1) Stainless steel on black. 22. Cab Interior a. Replace missing stud for cab pads. b. Replace ceiling with new LED light fixtures and translucent panels. 23. Pit equipment and buffers a. Clean existing equipment and touch-up or repaint as required. b. New pit stop switch. 24. Key Switches a. Provide Best core locks at both car and hall. b. Provide Card reader capabilities