Specifications include, but are not limited to: TECHNICAL REQUIREMENTS 2.1 TS2, Type 1 Hybrid Cabinet 2.1.1 The cabinet shall have dual front and dual rear doors with vents on the front left and rear left doors only. 2.1.2 The cabinet shall be constructed of 0.125” aluminum. 2.1.3 The cabinet exterior shall have a natural unpainted aluminum finish. 2.1.4 The cabinet shall have a NEMA P cabinet footprint. 2.1.5 The cabinet doors shall have a 3-point locking system using the industry standard traffic #2 key. 2.1.6 The cabinet shall have a “Police Panel” accessible from the outside that includes one switch for Normal / Flash operation, one switch that activates Manual Control Enable and one ¼“plug that controls Manual Control operation. 2.1.7 The cabinet shall include a front facing switch panel that includes switches for Normal / Flash operations, Run / Normal / Stop Time operations, Controller ON / OFF operations and one Fan Test button or switch which turns the cabinet fans on regardless of thermostat condition. See Figure 1 for location. 2.1.8 The cabinet shall incorporate two (2) standard Electronic Industries Alliance (EIA) 19” racks. 2.1.8.1 The cabinet shall include two (2) rack-mounted, 8” deep din rail panels. 2.1.9 The cabinet shall include facilities and field terminals for 8 phases, 4 pedestrian phases and 4 overlaps.