Specifications include, but are not limited to: Structure Specifications: The fabric structure shall meet the following specifications: - Dimensions: 40’ Wide X 60’ Long X 21’ Center Height - Fabric: 18OZ Translucent white, flame retardant, PVC fabric with polyester scrim, meeting the State of NH Fire Marshall Code and NFPA 701 standards. Or metal roofing that meets snow load for Claremont NH. - Frame Members: 24” heavy wall galvanized tubular steel truss design, with all weld joints coated with 97% zinc "cold gal" for corrosion protection. - Truss Spacing: Trusses are to be on 7.5’ centers. - Fabric Ends: Fabric ends at the base of the shelter with a skirt covering the base rail. - Access End Wall: Including 1 each: 12’ wide x 14’ high fabric access panel. Access panel door to include all winches, trolleys, pulleys, cables. - Man Door: Provide a outdoor rated man door for convenient access. - Electric Winch Door: Include an electric winch door with a manual override. In the case of power failure, a generator or manual rope/cable can be used to open or close the doors. - Compliance: The fabric structure must meet local building codes regarding wind and snow loads and exposure requirements. - Foundation: Anchors are included for an asphalt foundation. - Tensioning: Includes 1ea. 18” deep well socket for cover tensioning. - Securing: Includes 1” flat bar and tech screws/drive pins for securing the skirt back to the base rail or concrete. Requirements: Vendors interested in providing the structure must submit proposals addressing the following: - Detailed description of the proposed fabric structure, including compliance with specifications. - Information on the quality and durability of materials used. - Installation plan, including timeline and any special requirements. - Warranty information. - Cost breakdown, including supply, delivery, and installation. - References from previous clients with similar projects