Specifications include, but are not limited to: METAL GUARD RAIL--WROUGHT Design, fabricate, prime, topcoat and install a one-piece steel railing of 2" flat top and bottom rails and 1/4" balustrades 6" on center. INSTALL AT THE REAR ENTRANCE; TEAR OFF AND REROOF SHINGLES Remove and dispose of all roofing and defective sheathing. Synthetic felt and plastic cap fasteners. Install ice and water shields in all valleys. Install preformed aluminum, drip edge and vent pipe boots. Install metal flashing around chimneys and metal wall flashing to prevent water intrusion, seal and caulk. Install a 220 lb fiberglass asphalt, 3 tab shingle with a 25 year warranty. Replace all flashing pipe vents and install 2 turbines. Labor will require 5 ye; Fascia 1"x 6" Install a 1"x 6", #2 pine fascia with bevel cut joints using galvanized finished nails. Caulk over joints, and prime. Soffit- Install a 3/8" BCX plywood soffit. Prime and Match existint paint; REPAIR HOUSE ELECTRICAL SYSTEM Repair or replace all fixtures to meet current electrical code requirements including junction and outlet boxes, smoke detectors, outlet switches, cover plates, and all other components of the electrical system. INSTALL TO CODE; SUBSFLOOR--1/2" Install 1/2", tongue and groove, CDX plywood decking, nailed 8" on center using screw shank or cement coated nails. REPLACE ALL BAD SUB FLOORING AROUND TOILET AND INTERIOR DOORWAY