Specifications include, but are not limited to: 1. Market St. at Hinesburg Rd.: Contractor shall remove existing 6x6x6 tee and gate valves and install a new 6x6x6 tee and three-valve assembly. Market St water line may require a 6”x8” reducer. Department shall furnish gate valves, tee, Foster adapters, PVC C900 pipe, retainer glands, Hymax couplings, and valve boxes with lids. The Contractor shall provide crushed stone bedding, precast concrete thrust block and suitable backfill materials. The Contractor shall restore the site to match existing conditions including curbing, concrete sidewalk, and Type II bituminous pavement repair (up to 6” thick), etc. as necessary. 2. Barrett St. at Hinesburg Rd.: Contractor shall remove existing 6x6x6 tee and gate valves and install a new 6x6x6 tee and three-valve assembly. Department shall furnish gate valves, tee, Foster adapters, PVC C900 pipe, retainer glands, Hymax couplings, and valve boxes with lids. The Contractor shall provide crushed stone bedding, precast concrete thrust block and suitable backfill materials. The Contractor shall restore the site to match existing conditions including curbing, concrete sidewalk, and Type II bituminous pavement repair (up to 6” thick), etc. as necessary. 3. Iby St. at Hinesburg Rd.: Contractor shall remove existing 6x6x6 tee and gate valves and install a new 6x6x6 tee and three-valve assembly. Department shall furnish gate valves, tee, Foster adapters, PVC C900 pipe, retainer glands, Hymax couplings, and valve boxes with lids. The Contractor shall provide crushed stone bedding, precast concrete thrust block and suitable backfill materials. The Contractor shall restore the site to match existing conditions including curbing, concrete sidewalk, and Type II bituminous pavement repair (up to 6” thick), etc. as necessary.