Specifications include, but are not limited to: 1. HOUSELIGHTS: a. Maintain existing Houselights fixtures, dimmers, circuits, and controls. b. Furnish and install new LED A-Lamps for under Balcony fixtures. Contractor shall guarantee suitability for smooth, flicker free operation using existing dimming and controls. c. Furnish and install new LED Light Engine Retrofits for existing Houselights fixtures. Contractor shall guarantee suitability for smooth, flicker free operation using existing dimming and controls. d. Repair existing circuits, dimmers, controls, and lamp bases as necessary for a complete and working system. 2. LIGHTING CONTROL CONSOLE: a. Maintain existing ETC Ion Lighting Control Console. Configure, patch, and demonstrate proper operation and control LED Performance and House Lighting Fixtures as Specified. b. Provide (4) hours of training in the correct Operation and Maintenance of the existing Lighting Control Console, 3. FRONT OF HOUSE CATWALK: a. Maintain existing Front of House Catwalk. b. Disconnect and remove existing connector strips, maintaining load circuits for connection to new Power and Data Distribution Equipment. c. Furnish and install new Power and Data Distribution Devices, including necessary DMX-512A/ RDM Data Lines d. Furnish and install new LED Performance Lighting Fixtures. e. Repair or replace Pipe Batten to Support Theatrical Lighting Fixtures as necessary to support new equipment consistent with modern standards of safety and function. 4. #1 ELECTRIC BATTEN a. Maintain existing #1 Electric Batten. b. Disconnect and remove existing connector strips, maintaining load circuits for connection to new Power and Data Distribution Equipment. c. Furnish and install new Power and Data Distribution Devices, including necessary DMX-512A/ RDM Data Lines d. Furnish and install new LED Performance Lighting Fixtures. e. Repair or replace Pipe Batten to Support Theatrical Lighting Fixtures as necessary to support new equipment consistent with modern standards of safety and function. New Batten shall be a Double Pipe Batten Assembly. 5. #2 ELECTRIC BATTEN a. Relocate #3 Electric Batten approximately (2’) Upstage of the Mid-Stage Traveler Curtain. New Batten shall be a Double Pipe Batten Assembly. b. Disconnect and remove existing connector strips and/or cabling, maintaining load circuits for connection to new Power and Data Distribution Equipment. c. Furnish and install new Power and Data Distribution Devices, including necessary DMX-512A/ RDM Data Lines. Circuits for new Power Distribution to be re-routed from existing #2 Electric Junction Box or #1 Electric Junction Box. d. Furnish and install new LED Performance Lighting Fixtures. e. Repair or replace Pipe Batten to Support Theatrical Lighting Fixtures as necessary to support new equipment consistent with modern standards of safety and function. New Batten shall be a Double Pipe Batten Assembly. 6. #3 ELECTRIC BATTEN a. Relocate #3 Electric Batten approximately (18”) Upstage of the #3 Border Curtain. b. Disconnect and remove existing connector strips and/or cabling, maintaining load circuits for connection to new Power and Data Distribution Equipment. c. Furnish and install new Power and Data Distribution Devices, including necessary DMX-512A/ RDM Data Lines. Circuits for new Power Distribution to be re-routed from existing #2 Electric Junction Box or #1 Electric Junction Box. d. Furnish and install new LED Performance Lighting Fixtures. e. Repair or replace Pipe Batten to Support Theatrical Lighting Fixtures as necessary to support new equipment consistent with modern standards of safety and function. New Batten shall be a Double Pipe Batten Assembly. 7. #4 ELECTRIC BATTEN a. Maintain existing #4 Electric Batten. b. Disconnect and remove existing connector strips, maintaining load circuits for connection to new Power and Data Distribution Equipment. c. Furnish and install new Power and Data Distribution Devices, including necessary DMX-512A/ RDM Data Lines d. Furnish and install new LED Performance Lighting Fixtures. e. Repair or replace Pipe Batten to Support Theatrical Lighting Fixtures as necessary to support new equipment consistent with modern standards of safety and function. New Batten shall be a Double Pipe Batten Assembly.