Specifications include, but are not limited to: A. Remove lead from earthen backstops for a minimum depth of six (6) inches for the entire face of the berm. B. Remove lead from the main bullet impact zone to a minimum depth of twenty-four (24) inches. The main impact zone location is determined by the location of each shooting position or station at the firing line. The main impact zone for each range is describes as follows: • Shooters Public Range 50 yd.: should be right at the toe of the berm and up one-hundred eighty (180) inches, full length of the berm. • Shooters Public Range 100 yd.: should be right at the toe of the berm and up to one-hundred twenty (120) inches, full length of the berm. • Shooters Public Range 200 yd.: should be right at the toe of the berm and up to seventy-two (72) inches from the top, full length of the berm. • Shooters Education Center 50 yd.: should be right at the toe of the berm and up to one-hundred twenty (120) inches, full length of the berm. • Shooters Educations Center 100 yd.: should be right at the toe of the berm and up to one-hundred twenty (120) inches, full length of the berm. C. Any clean soil that results from the lead screening process will be reinstalled on the berm. D. Re-establish any berms or grades where berms will have a face slope of 1:1 and a minimum height of twenty (20) feet for all berms. E. All reclaimed areas shall be returned back to original grade, free of rock and material piles. F. Deliver all reclaimed lead to a COUNTY approved recycling facility.