Provide Labor, Materials, Services, Supplies, Tools, Equipment, Permits, Transportation and Facilities necessary to furnish and install the complete and operable systems as called for in the plans. To improve the comfort and health of employees and patrons the City of Claremont N.H. is seeking Qualified HVAC contractors to facilitate a new system in the City Hall /Opera House office areas. The overall goal is to install a system that is responsive to year-round temperature fluctuation within the workplace with increased air quality. The current split system that occupies most of the offices for A/C and added heat will be removed and disposed of by the awarded bidder while keeping the baseboard hydronic system in place and functioning. All areas of this install are assessable through suspended ceilings or above ceiling crawlspace. The contractor will be responsible for all electrical, & plumbing. On completion of the project, all areas of ceilings, walls and floors will be left finished off as good or better than commence of job unless approved by the Maintenance Supervisor. Provide and install the following materials; 1. Three (3) 48,000 Btu Mitsubishi Hyper Heat H2i Ductless Split heat Pump System M/N: MXZ-SM48NAMHZ2-U1 2. One (1) 42,000 Btu Mitsubishi Hyper Heat H2i Ductless Split heat Pump System M/N: MXZ-SM42NAMHZ2-U1 3. Two (2) 36,000 Btu Mitsubishi Hyper Heat H2i Ductless Split heat Pump System M/N: MXZ-SM36NAMHZ2-U1 4. One (1) 18,000 Btu Mitsubishi Ductless Split Cooling Only System M/N: PKAA18NKA7 5. One (1) 18,000 Btu Mitsubishi “PKA” series indoor wall mounted unit M/N: PKAA18HA4 6. Three (3) 15,000 Btu Mitsubishi "FS" serres Indoor wall mounted unit M/N MSZ-FS15NA 7. Four (4) 12,000 Btu Mitsubishi "FS" serres Indoor wall mounted unit MIN MSZ-FS12NA 8. Five (5) 9,000 Btu Mitsubishi "FS" serres Indoor wall mounted unit M N MSZ-FS09NA 9. Fifteen (15) 6,000 Btu Mitsubishi "FS" serres Indoor wall mounted unit MIN MSZFS-06NA 10. Construct five (5) condenser pads with crushed granite and Quarry cut 2" lh1cl< blue slate stone 11. Five (5) snow stand to support the condensing unit off ground 12. Two (2) wall brackets 13. Type ACR insulated refrigerant lines 14. Pressure test new line set with 500 PSI Dry Nitrogen 15. Evacuate line set, add in additional refrigerant charge required for proper system operation 16. WHITE exterior or interior line hide to conceal exterior refrigerant lines 17. Condensate drain lines as necessary 18. Twenty-eight (28) MITSUBISHI KLIMO Cloud Wi-Fi Adapters, including a tablet set up as the main control 19. Low voltage control wiring as required 20. Line voltage wiring as required