Specifications include, but are not limited to: Open Timber Truss Gables: MATERIAL AND QUALITY ASSURANCE; Standard glue laminated timber shall be in conformance with AITC Standard (latest edition). Species: Laminating lumber shall be kill-dried, architectural grade, sealed and wrapped. The roof system for wood structures and buildings are designed to withstand 30PSF live load and 20 PSF wind load. The standard roof slope shall be 4/12. Laminated Support Columns: MATERIAL AND QUALITY ASSURANCE; Structural glue lamination timber shall be in conformance with AITC (latest edition). Species: Laminated columns shall be sized to suit loading requirements. Manufacture shall furnish connection steel and hardware for joining structural glue laminated timber members to their supports, exclusive of anchorage and embedment in masonry or concrete. Connector Plates: Plates shall be fabricated from structural steel ASTM-A-36. Plates to be powder coated black. Hardware: A-325 zinc plated machine bolts and nuts...