Specifications include, but are not limited to: 1. SCOPE OF WORK: General conditions are listed below. Door County wishes to contract with a reputable contractor and receive proposals that fit the general specifications. The request for proposal is as much prescriptive as it is specified. 2. Dimension: 40’0”X64’0”X15’8” overall 3. Details: Truss (Raised Lower Chord) with 5/12 roof pitch. Default ceiling design: designed to support a future drywall ceiling Type of Foundation: In Ground Concrete floor 2400sq ft 4” slab with thickened edge 50 psf Ground snow load with 2’x4’ Continuous 2’0” on center purlins 4. Exterior Finishes: Roof/Siding: PLP Prime G90 Lifetime film integrity warranty, 35 year fade and chalk warranty, and G-90 Galvanizing 5. Details of intent Standard Ridge Cap Marco LP2 Weather-Tite Ridge Vent “Low profile” (add ventilation to the ridge) Side Wall Overhang: 18” Aluminum soffit (side wall) with vented soffit End Wall Overhang: 18” Aluminum soffit (end wall) with non-vented soffit Open Wall Bay – All Bays – From 0’0” to 64’0” with J trim Clearance height: 14’0”