Specifications include, but are not limited to: • Manufactured in the year 2024 or later • All machine, transducers, and associated equipment must be NEW and manufactured in the year 2024 or later (demo and refurbished not accepted) • All machines and transducers must be the same brand with the exception of wireless transducers as described below • Strain Elastography required • Scan assist technology must be available and active • Must have 4 active probe ports • USB, DICOM, DVR Capability Required • 20 inch, high resolution LCD monitor or larger • Monitor and panel must be height adjustable, and panel must be 3 plane maneuverable. Monitor must have swivel capability • OB measure assist required • B-Mode, spectral doppler, M-Mode and color doppler, measurement and annotation raw data post processing • Integrated gel warmer • Speckle Reduction Imaging • Post processing gain, TGC, zoom and doppler capabilities • ONE machine must include the following transducer: Hockey Stick transducer with a bandwidth of 5-18 MHz. Transducer MHz must fall within this range with a minimum max of MHz of 14 MHz. • ONE machine must include the following transducer: Endocavitary transducer with bandwidth of 5-9 MHz. Transducer MHz must fall within this range. • TWO machines must include the following transducers: o Sector array transducer with a broad bandwidth of 1.0 – 7.5 MHz for cardiovascular and TCD scanning. Transducer MHz must fall within this range. • ALL machines must include the following transducers: o Convex 4D lightweight probe o Convex Array Transducer with a broad bandwidth of 1-7 MHz. Transducer MHz must fall within this range. o Linear Array Transducer for the purpose of vascular scanning, with broad bandwidth of 7 -15 MHz. Transducer MHz must fall within this range. o Linear Array Transducer for the purpose of small parts scanning with bandwidth of 6-20 MHz. Transducer MHz must fall within this range AND the minimum accepted top range is 15 MHz. o Wireless dual transducer with the following specifications: o BOTH curved and linear array scanning capability. The bidder may bid two separate wireless transducers in place of a single transducer if necessary to meet the linear and curved specification. o This transducer must be able to connect to Android and IOS tablets and function seamlessly with the ultrasound machine. o These transducers do not have to be the same manufacture as the machines but must function seamlessly with the quoted machines without any loss of functionality. o Transducer must be able to perform B-Mode, color doppler, M-Mode, and pulsed wave doppler imaging.