Specifications include, but are not limited to: Mobilize Aerial Lift (no sidewalk, street and building permits included) Bio clean • Bio Clean all masonry with Enviro Klean by Prosoco and hot water approx. 180 degrees at no more than 400 p.s.i. Tuckpoint 120 square feet of brick • Grind with dustless vacuum per OSHA Guidelines • Grind min. ½” in depth or to sound mortar. • Lightly rinse ground mortar joints to remove any contaminates or loose material. • Install Type “N” mortar. • Tooling, texture, and color to match existing. Mortar to set no less than seven (7) days prior to washing with detergents to expose sand. Cutout and recalk Window Perimeters • Remove existing sealant from window perimeters. • Clean and prep both edges • Solvent wipe • Install backing to proper depth. o Apply silicone sealant by Tremco with no less than 100% elasticity, tooled to a concave finish. o Pending on manufacturer sealant priming may be required. • Pull and adhesion testing of sealant will be required prior to installation...