1. Exterior lead testing to determine proper disposal of waste materials, proper PPE during construction, and allow for remediation if lead paint is present. 2. Foundation stabilization and repair of the 10’ x 28’6” back storage room attached on the east side of the building. 3. Primary work replacement, renovation, and repair of exterior walls of the 78’x 30” building. a. Window replacement i. The building features 31 existing windows (Dimensions of windows are approximately as follows) 1. 13 (3’ x 4’) 2. 11 (3’ x 6’) 3. 2 (2’x 3’) 4. 1 (2’ x 2’) 5. 1 (6’ x 4’) 6. 1 (4’x 4’) 7. 1 (6’ x 6’) Double window 8. 1 (5’ x 3’) ii. Argon double-pane glass window replacements b. Exterior door replacement i. Energy efficient replacement for three exterior doors. 1. Two single doors (approximately 3’x 6’6”) 2. Double door associated with loading zone (each door approximately 3’ 6’6”) ii. Removal of two unused/unusable doors. c. Replacement of siding i. Replacement of exterior cladding with insulated vinyl siding. ii. Installation of a vapor/air barrier iii. Repair/replacement of intermediate siding as needed iv. Replacement of skirting v. Replacement of skirting door leading to outdoor storage under building. vi. Finish and trim associated with replaced doors and windows. 4. Additive Improvements (as possible) i. Insulation of exterior walls and flooring ii. Upgrades and repair to the electrical system