(CU 101375) CABLE, INSULATED TYPE: CONTROL CABLE SIZE: #10 VOLTS: 600 V CABLE MATERIAL: COPPER NO. CONDUCTORS: 4 SOLID/STRANDED: 7 STRAND INSUL. MATERIAL: POLYETHYLENE TEMP. RATING: 75 DEG C JACKET MATERIAL: PVC LENGTH: 1000 FT ADDITIONAL DESCRIPTION: (CU 101375) 4 CONDUCTOR, 600 VOLT, 75 DEGREE C, CONTROL CABLE WITH #10 AWG, 7 STRAND COPPER, 20 MIL POLYETHYLENE AND 10 MIL PVC INSULATED CONDUCTORS (20PE/10PVC) AND POLYVINYL CHLORIDE (PVC) JACKET. CONTROL CABLE APPROXIMATE OUTSIDE DIAMETER IS 0.57 INCHES. CONDUCTORS TO MEET REQUIREMENTS OF ICEA SPEC. #S-61-402 AND ASTM SPEC. #D-1248-12 AND NEMA #WC5 AND BE UL-LISTED. CONTROL CABLE TO BE SUITABLE FOR UTILITY COMPANY SUBSTATION AND POWER PLANT CONTROL CIRCUITS. WIRE TO BE SUITABLE FOR USE IN OPEN AIR, AERIALLY, DUCTS, TRAYS, CONDUIT OR DIRECT BURIAL, INDOORS OR OUTDOORS, WET OR DRY LOCATIONS. CABLE SHALL BE SUNLIGHT RATED. EACH CONDUCTOR SHALL BE UTILITY COLOR CODED PER ICEA METHOD #1 TABLE E-1 AS SHOWN ON THE CONDUCTOR COLOR CODING TABLE LISTED BELOW. OUTER SURFACE MARKINGS SHALL IDENTIFY MANUFACTURER, NUMBER OF CONDUCTORS, TYPE 20-10, SIZE AND VOLTAGE RATING. EACH REEL FURNISHED SHALL BE TAGGED WITH TOTAL FOOTAGE; GROSS, TARE, AND NET WEIGHT; TYPE OF CONDUCTOR AND MANUFACTURER'S NAME; AND DATE OF MANUFACTURER. * CONDUCTOR COLOR CODING TABLE (METHOD #1 TABLE E-1) CONDUCTOR CONDUCTOR NUMBER COLOR --------- --------- 1 BLACK 2 WHITE 3 RED 4 GREEN * ANY OTHER COLOR CODING WILL NOT BE ACCEPTABLE!! * NOTE: PLEASE SUBMIT MANUFACTURER'S CATALOG NUMBER, AND CABLE TYPE, AND CATALOG DATA INFORMATION WITH BIDS. * ACCEPTABLE ALTERNATIVE ORDERING DESCRIPTION: * UTILITY COLOR CODE METHOD #1 TABLE K-1 CONTROL CABLE EXACTLY LIKE ABOVE SPECIFICATION, EXCEPT INSTEAD OF: "75 DEGREE C, 20 MIL POLYETHYLENE, 10 MIL PVC INSULATED CONDUCTORS AND PVC JACKET PER ICEA #S-61-402" & 0.57" O.D., THE FOLLOWING ALTERNATE MAY BE FURNISHED: "HEAT, MOISTURE, FLAME AND CHEMICAL RESISTANT INSULATED CONDUCTORS 'TYPE TC', 90 DEGREE C DRY, 75 DEGREE C WET, 30 MIL ETHYLENE-PROPYLENE (OR ETHYLENEPROPYLENE RUBBER) ON EACH SINGLE CONDUCTOR, AND NEOPRENE OR HYPOLON (CPE) OVERALL OUTER JACKET PER ICEA #S-68-516 REQUIREMENTS. THE CABLE APPROXIMATE OUTSIDE DIAMETER SHOULD BE 0.67 INCHES." SPLICE, COMPRESSION COPPER. COPPER SPLICE + COVER FOR 1/0 COPPER WIRE. (CU 105025) WOOD ALLEY ARM BRACES. BRACES SHALL BE MADE FROM 2-3/4" X 3-3/4" WOOD SECTION OF CLEAR, STRAIGHT GRAINED DOUGLAS FIR AND SHALL BE TREATED WITH 6# PENTACHLOROPHENOL AND MEET SPECIFICATIONS OF THE AMERICAN WOOD PRESERVER'S ASSOCIATION. ARM SHALL BE FURNISHED WITH HOT DIPPED GALVANIZED END FITTINGS. BOLT HOLES FOR CROSS ARM FITTING SHALL BE 11/16". LENGTH FROM CENTER OF BOLT HOLES IN END FITTINGS SHALL BE 5 FEET. BRACE SHALL BE ASSEMBLED WITH ARM FITTINGS TO ATTACH TO BOTTOM OF ARM AND POLE FITTING TO ATTACH TO FACE OF POLE.