Electrical work includes power and control wiring for new entry and exit sliding gates at Security #1, along with a wireless intercom system to Central Control for both gates. New high security gates 30A and 32A at the existing vehicular sallyport near control tower 12 shall also be wired for power, control and accessories as shown in the drawings. Existing Gate 30 shall have the operator replaced. Sallyport gates shall be interlocked with existing Gate 3 to the main secure compound. Site work includes approximately 2,254 lf of new fencing is to be installed around the western portion of the secure perimeter. The new fencing will be parallel to the existing outer perimeter fence. The new fence will be 10 tall with eight coils of razor wire. The new perimeter fence will also provide for two pedestrian gates to access the no mans land between the fences. The no mans land space between the fences will be receive 6-inches of KYTC crushed stone. At the main vehicular entrance to the secure perimeter two new 20 wide by 15 tall vehicular slides gates will be installed with slide drivers controlled from tower 12. At the box security checkpoint on to the grounds of the facility two new 5 tall by 18 wide slide gates and slide drives will be installed.