The Contractor shall furnish all labor, equipment, materials and all else necessary for the overhead door replacement as described below: • Removal and disposal of the existing fire bay door, including all tracks, brackets, springs, operators, and all other related items not being reused. • Furnishing and installing a 13’ 2” x 12’ Flush Panel Steel Insulated Overhead Door. ➢ Panel Design – Micro Grooed ➢ 2” Thick Sections ➢ Installation R-Value = 17.54 ➢ Color: White ➢ 15” Radius Heavy Duty Track ➢ Torsion Springs ➢ 3 rd Section – Row of Insulated Oval Windows ➢ Exterior Weather seal Package. • Full Duty Commercial Duty Operator/Motor Quantity – 2 ➢ ½ HP ➢ Full Heavy-Duty Rail ➢ Solenoid Brake System ➢ Button Wall Station ➢ Safety Photo Eyes ➢ Remote ➢ Provide all electrical work for power and control circuits. ➢ Removal and disposal of all removed equipment/materials/debris and clean-up of the work areas. ➢ Start-up, testing and adjustment of the new door.