Controller • Two-way Communication Machine Room Equipment (Primary Box) • TAC 32 Controller (Includes Options listed below) o 24 VDC Signal Voltage o Auto Light and Fan Feature o Car Independent Service o Car Traveling Lantern Circuitry o Door Bypass Operation o Electronic Door Detector Interface o Hoistway Access and Enable o THY Board • Solid State Starters (6 or 12 leads) 208 VAC • Battery Lowering in Controller • Viscosity Control (Required over 150 FPM) • eMax Monitoring Device Provisions Power Unit • 5 gallon drum of Biodegradable oil (Citgo NZ) • 55 gallon drum of Biodegradable oil (Citgo NZ) • EP-80 Power Unit (Submersible) • 2" Shutoff Valve Kit (Pump) • Viscosity Control (Required over 150 FPM) Jack • Pipe Stands Car • Crosshead data tag (for existing car slings) • Fan: Two Speed • Car Top Exit Switch • Two-way Communication Camera (dome), Ethernet Extender (kit), & Battery Backup • Cab Wiring Material (200MK1)