The Vendor shall supply five (5) Metering Pumps that comply with the following specifications: 1. The Metering Pumps shall be: i. LiquiFlow H3F H-Series Gear Pump, or exact equal ii. Part number – H3FC1K3EU000000, or exact equal iii. Alloy -C, or exact equal 2. The Metering Pumps shall be provided with the following prime mover: i. WEG ½ hp, 56C motor, or exact equal a. 1160 RPM b. 3 phase, 480v c. 60 Hz ii. Motor shall be a. Constant torque VFD approved 3. The pumps shall have the following general specifications: i. Gear pumping chamber (driven and idler gears) ii. Design flow rate - 35 GPH iii. 15 PSI discharge iv. 1.76 NPSH v. Alloy-C construction, or exact equal vi. Designed RPM - 870 vii. Max temperature - 500° viii. ANSI 150# flanges...