1. Remove all existing asphalt shingle roofing and underlayment down to the wood substrate, haul away and dispose of in accordance to local ordinances. 2. Inspect the existing structural substrate for damages and replace with same materials if panels are found to be dangerous and/or structurally unsound. This includes fascia boards. 3. Furnish and install new ice & water membrane at eaves and protrusions. Peel & Stick membrane must be adhered to wood substrate and extend a minimum 3’ up the slope beyond the exterior wall. 4. Furnish and install new #15 organic felt underlayment. Two ply felt application required on all slopes less than 4/12. 5. Furnish and install new drip edge fabricated from .024 aluminum. 6. Furnish and install new gutters & downspouts profile to match existing. 7. Furnish and install new dimensional fiberglass shingle, color to be selected by owner, meeting: Applicable Standards • ASTM D 3018, Type I • ASTM D228 • ASTM D 3462 • ASTM E 108 Fire Resistance: Class A • ASTM D 3181 Class H Wind Resistance • ASTM D 7158 Class H Wind Resistance • UL 2390/ASTM D6381 Class H Wind Resistance • UL 790 Fire Resistance: Class A • UL 997 Wind Resistance