1) Apply materials in accordance with manufacturer's recommended application instructions. 2) Apply undiluted waterproofing material in the number of coats recommended by manufacturer by means of airless spray. Completely coat masonry, including mortar joint surfaces. Areas adjacent to openings, or to other types of wall construction, may be covered by means of brush or roller subject to approval; otherwise, adjacent features such as doors or windows must be masked. 3) Minimum equivalent coating rate shall equal 120 square feet per gallon for solvent based material and 80 square feet per gallon for water-based materials. 4) PRODUCTS - Waterproofing Specifications 5) Product type must be a clear, penetrating, non-surface coating, which upon application, forms a sub-surface waterproof barrier. Silicone formulations will not be acceptable. Product shall be Chemstop "Heavy Duty Masonry Waterproofing"; Dunn-Edwards "Okon W-2"; Kelly-Moore "Kel-Seal 99"; or equal...