Fire Resistive Construction: As Required by code. Interior Walls and Partitions: The construction will be abuse resistant gypsum board. All partitions do not have to go to the underside of deck and could be trimmed and a top capping to match the existing partitions in the space above ACT ceiling. FPR paneling over moisture resistant gypsum board to be used in any wet areas. Wall Finishes: All areas finished in masonry: To have 3 coats water base system. Primer: Primer Sealer (on drywall) or Masonry Filler (on concrete block). Finish: 2 coats of epoxy coating. Colors to be as selected by the Architect. All areas finished in Gypsum wall board: Provide primer plus two (2) finishing coats of alkyd paint system, eggshell or satin finish. Toilet rooms shall have porcelain tile and glass accent on wet wall tile and “epoxy” or “scuffmaster” painted walls extending from floor to ceiling height Floor Finishes: Any exiting flooring is to be removed throughout with epoxy resin flooring installed over existing and new floor slab areas. The Entry Lobby and associated vestibules are to receive an entry carpet mats with ADA Compliant edges. Toilet rooms: New Porcelain tile. Provide appropriate transition at dissimilar floor materials. Rubber base: 4” high, extruded rubber cove base, set-on-type, with preformed corners. Provide field formed end stop units where base terminates or abuts openings. Rubber base to be used at all locations...