1.1 Rear Wall Sconce Repair Contractor to investigate and repair four non-working wall sconce fixtures i. Contractor to investigate and repair these four non-working fixtures on house circuit 188. 1.2 House Light Control Stations Contractor to install ETC Paradigm Inspire house light control wall stations in house at three (3) locations as noted. i. Contractor must use existing single-gang flush-mounted boxes as noted for house left and right control station locations . ii. Contractor must use existing four--gang flush-mounted box house center control station. RTHS will supply an adapter plate. iii. Pull Belden 8471 wire, or equivalent, to interconnect each location and to dimmer room. Topology is free and polarity independent, you may install the wires in any combination of bus, star, loop, or home-run. iv. Terminate cables at wall stations. v. Dimmer rack termination will be by others. vi. Wall stations will be programmed by others. 1.3 Lighting Data Cable Installation Contractor to pull CAT5e cable from existing data rack to 18 locations as as noted on attached drawings. i. Pull contractor supplied CAT 5e UTP, 24AWG, 100Mhz data cable (or higher) from data rack to 18 locations in facility as marked. ii. In a few noted locations, cable must terminate into existing flush-mounted gang boxes through existing conduit. iii. New data drop locations may be run through free-space, by bridle-ring, with cable-ties. They need not be located in conduit, as long as the paths chosen do not transit walk-ways, steps, railings, etc. and that no potential safety risk, or damage to the cable is present. iv. Contractor to supply and install a 1900 box with a single-gang plaster ring at 18 locations. Cable may enter through a cable bushing. Mounting may be via beam clamp or screw. v. Cables must be labeled at both ends for identification. vi. Terminate both ends of cable with a contractor supplied RJ45 connector and boot rated for compatibility with the installed cable. vii. Contractor will test all data cable runs for correct termination. viii. Contractor will connect and install RTHS supplied custom legend single-gang RJ45 wall plate at each location. (Each plate contains one pass-through RJ-45 connector) ix. Lighting data network will be programmed by others.