1) Proposal to include a three year service agreement for the existing Turblex Blowers (Model KA10-SV-GA250, S/N: 4993, 49944, 4995). The agreement should include the following: a. One visit annually to provide inspections to three existing Turblex blowers and Class I service. i. Class I service to include the following: repeat annual inspection, dismantle compressor air-end, remove gearbox access covers for visual observation of internal condition, inspect and clean variable vane system, check variable vane geometry, check axial movement on high and low speed shafts, and check unit alignment before re-start as required. b. Any typical replacement parts for a Class I service. c. The ability to perform a Class II service if necessary. i. Class II service to include the following: repeat Class I inspection, dismantle gearbox, inspect (gearwheels, bearings & seals and check clearances, adjust clearances as required), replace flexible seals/O-rings, reassemble gearbox, visually inspect (electric motor, oil pump, oil cooler, coupling valves, etc.) and provide recommendations for corrections of unusual findings and future services.