• Monolithic Slab & Footing (Design & Construction) • 42’ x 81’ Clear Span PEMB (Design & Construction) • Gabled Roof with 4:12 Roof Pitch • 2" closed cell spray foam insulation - walls and ceilings • Interior lighting • Exterior Lighting • Wall outlets • Wind Load of 125 MPH • Trenched concrete foundation, capped by floor slab • Laminated wood columns to be mounted to concrete foundation with steel column sockets using adhesive anchor rods • Treated wood splashboard system • Siding: Minimum 1000 Hi-Rib steel .019 on north, south, east, west walls without wainscot • Roof: hi-Rib steel minimum .019 fastened with stainless steel screws • Overhangs: West, east wall(s) 1’ wide vented sidewall overhang with standard 6” fascia, 5” gutters and 3”x4” downspouts, with elbows at base • Overhangs: Sout, north walls 1’ wide non vented endwall overhang with standard 6” fascia • Condensation control: Roof, formed by dry-panel • Walk Doors: 3’ x 6’8” MB plain flat lead walk doors in swing right hinge with interconnected lever lockset/deadbolt • Overhead door opening: 10’2” x 10’1” panels • Overhangs: West, east wall(s) 1’ wide vented sidewall overhang with standard 6” fascia, 5” gutters and 3”x4” downspouts, with elbows at base