1. lnstall a 60-mil roofing system, either TPO single ply membrane or 60-mil silicone or polyurethane fluid-applied membrane roofing system according to the manufacturer's specifications, includ ing : 2. Remove and dispose of existing roof membrane down to the existing cover board per manufacturer specifications (in the case of TPO) or remove loose walk-pads and clean existing roof membrane per manufacturer specifications (in the case of fluid-applied). 3. Flash all roof penetrations utilizing standard manufacturer-approved details. 4. Remove existing metal cap flashing and save for reuse. 5. Flash all parapet walls full height and across the top with adhered or fluid-applied mem brane flash i ng/roofing. 6. Re-install the existing metal cap flashing. 7. Remove all construction debris from the site and dispose of all rubbish properly. 8. Provide manufacturer inspections and a 2}-year manufacturer labor and materials warranty with 90 mph or higher wind speed coverage. 9. Provide manufacturer's certification for installer/applicator 10.See Attachment A for wet areas of roof.